CBG Corp, state-of-the-art logging tools and sensors

DGA Focused Gamma Tool Specifications

Overview | Specifications
DGA
FOCUSED GAMMA
Application Geosteering/MWD
Mechanical
Diameter (OD) 1.36″
Length (make up) 13.6″
Weight 3.0 lb.
Operating Temperature -77 to +350 °F
End Connectors MDM 15-Pin
Material Aluminum Alloy/Tungsten
Pressure NR
Performance
Sensitivity 0.6 Counts per API
Accuracy +/- 5% to 300°F.
+/- 10% to 350°F.
Front/Back Count Ratio 2.4
Angular Resolution (8″ hole) 75° / 360°
Thin-Bed Resolution (8″ hole diameter, at 50% points) 8.8″
Environmental
Survival Temperature 400°F.
Max Heat/Cool rate 5°F./Minute
Vibration (3 axis)
50-300 Hz
Random spectrum

30 G. RMS
Shock (Z-axis) 500 G., 0.5 mS.
Shock (X or Y-axis) 1000 G., 0.5mS.
Power Requirements
Input Voltage 22-30 Volts
Input Current 18-14 mA. (constant power)
Maximum Voltage 31.5 Volts
Output Signal
Negative Pulse +5V to GND.
1.5 to 3.5 uS