CBG Corp, state-of-the-art logging tools and sensors

Gamma Ray Tools Specifications

Overview | Specifications | PDF Brochure
CBG Corp. NGT-T Gamma Ray Tool: Click for larger image.
Gamma Ray Tool Specifications NGT-T
w/out housing assembly
NGT-T
with housing assembly
NGT-CS DGA
FOCUSED GAMMA
NGT-B NGT-S
Application Geosteering/ MWD Geosteering/ MWD Geosteering/ MWD Geosteering/MWD Wireline/ Production Wireline/ Production
Mechanical
Diameter (OD) 1.36″ 1.875″ 1.050″ 1.30″ 1.6875″ 1.375″
Length (make up) 13.6″ 34.05″ 18.83″ 13.6″ 22.25″ 25.2″
Weight 1.7 lb. 15.0 lb. 1.5 lb. 3.0 lb. 6.0 lb. 4.0 lb.
Operating Temperature -77 to +350 °F. -77 to +350 °F. -77 to +350 °F -77 to +350 °F -77 to +350 °F -77 to +350 °F
End Connectors MDM 15-Pin 200 °C, 10-Pin GE MDM 15-Pin MDM 15-Pin GO Single-Pin GO Single-Pin
Material Aluminum Alloy BeCu Aluminum Alloy Aluminum Alloy/Tungsten Ti-6Al-4V Ti-6Al-4V
Pressure NR 18,000 PSI NR NR 15,000 PSI 18,000 PSI
Performance
Sensitivity 2.0 Counts per API 1.7 Counts per API 1.8 Counts per API 0.6 Counts per API 1.8 Counts per API 1.6 Counts per API
Accuracy +/- 5% to 300°F.
+/- 10% to 350°F.
+/- 5% to 300°F.
+/- 10% to 350°F.
+/- 5% to 300°F.
+/- 10% to 350°F.
+/- 5% to 300°F.
+/- 10% to 350°F.
+/- 5% to 300°F.
+/- 10% to 350°F
+/- 5% to 300°F.
+/- 10% to 350°F
Thin-Bed Resolution (8″ hole diameter, at 50% points) 6.8″ 6.8″ 8.8″ 8.8″ 6.2″ 8.8″
Environmental
Survival Temperature 400°F. 400°F. 400°F. 400°F. 400°F. 400°F.
Max Heat/Cool rate 5°F./Minute 5°F./Minute 5°F./Minute 5°F./Minute 5°F./Minute 5°F./Minute
Vibration (3 axis)
50-300 Hz
Random spectrum
30 G. 30 G. 30 G. 30 G. 30 G. 30 G.
Shock (Z-axis) 500 G., 0.5 mS. 500 G., 0.5 mS. 500 G., 0.5 mS. 500 G., 0.5 mS. 250 G., 0.5 mS. 250 G., 0.5 mS.
Shock (X or Y-axis) 1000 G., 0.5mS. 1000 G., 0.5mS. 1000 G., 0.5mS. 1000 G., 0.5mS. 500 G., 0.5mS. 500 G., 0.5mS.
Power Requirements
Input Voltage 22-30 Volts 22-30 Volts 22-30 Volts 22-30 Volts 46-48 Volts 46-48 Volts
Input Current 18-14 mA. (constant power) 18-14 mA. (constant power) 18-14 mA. (constant power) 18-14 mA. (constant power) 20-23 mA 20-23 mA
Maximum Voltage 31.5 Volts 31.5 Volts 31.5 Volts 31.5 Volts 50 Volts 50 Volts
Output Signal
Negative Pulse +5V to GND
1.5 to 3.5 uS
+5V to GND
1.5 to 3.5 uS
+5V to GND
1.5 to 3.5 uS
+5V to GND
1.5 to 3.5 uS
CBG Telemetry or
Wireline Pulse
CBG Telemetry or
Wireline Pulse