CBG Corp, state-of-the-art logging tools and sensors
中文网站

NGT-B Gamma Tool Specifications

for Wireline

Overview | Specifications

When comparing cased-hole logs made by this tool with open-hole logs, it will be necessary to correct the readings for casing attenuation. This may be done by using the “Collar-Correction” graphs on our NGT-T web page if you know the casing thickness.

NGT-B Specifications
Application Wireline/ Production
Mechanical
Diameter (OD) 1.6875″
Length (make up) 22.25″
Weight 6.0 lb.
Operating Temperature -77 to +350 °F
End Connectors GO Single-Pin
Material Ti-6Al-4V
Pressure 15,000 PSI
Performance
Sensitivity 1.8 Counts per API
Range 0 to 10,000 API
Accuracy +/- 5% to 300°F.
+/- 10% to 350°F
Thin-Bed Resolution (7″ casing diameter, at 50% points) 6.2″
Environmental
Survival Temperature 400°F.
Max Heat/Cool rate 5°F./Minute
Vibration (3 axis)
50-300 Hz
Random spectrum

30 G. RMS
Shock (Z-axis) 250 G., 0.5 mS.
Shock (X or Y-axis) 500 G., 0.5mS.
Power Requirements
Input Voltage 46-48 Volts
Input Current 20-23 mA
Maximum Voltage 50 Volts
Output Signal

CBG Telemetry or Line Pulse