NGT-075 Gamma Tool Specifications

Overview | Specifications

The CBG NGT-075 third-generation Gamma tool offers advanced protection and noise-suppression circuits in a high-performance, reduced-size sensor.

CBG Corp. NGT-075 Gamma Ray Tool: Click for larger image.
NGT-075 Specifications
Application Geosteering/ MWD
Mechanical
Diameter (O.D.) 0.75″ (19.05 mm.)
Length (make up) 14.5″ (368 mm.)
Weight 8.5 oz. (240 grams)
End Connector Plug 7-pin circular, AirBorn MC-111-007-161-00WN-96M
Material Aluminum Alloy
Pressure NR
Performance
Typical Sensitivity 1.0 CPS per API
Accuracy +/- 2% to 300°F. (150°C.)
+/- 5% to 350°F. (175°C.)
Maximum API Range
(at 5% error)
10,000 API
Thin-Bed Resolution (In 8″ hole diameter, at 50% points) 6.8″ (172 mm.) at 50% points
Environmental
Operating Temperature -77 to +350°F. (-55 to 175°C.)
Survival Temperature 400°F. (204°C.)
Max Heat/Cool rate 5°F. (3°C.) per minute
Vibration (3 axis)
30-1000 Hz
Random spectrum
30 G. with no excess counts
Shock (Z-axis) 500 G., 0.5 mS. duration
Shock (X or Y-axis) 1000 G., 0.5mS.
Power Requirements (all tools use NexGen electronics)
Input Voltage +17 to +48 Volts DC
Input Current 11-8 mA. (9 mA at 28V)
Maximum Voltage 50 Volts
Output Signal
Negative Pulse +5 volts to GND
5 uS fixed width